Customization: | Available |
---|---|
Mass Scope of Workpiece: | <900kg |
Type: | Vibration Testing Machine |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical data at a glance | RS0 | RS1 | RS2 | |
rotor weight W(including adaptor) Occasional overload permitted up to provided the rotor weight is equally shared between the two bearings, i. e. per bearing pedestal | Max. Max. Max. | 3 kg 4 kg 2 kg | 10 kg 20 kg 10 kg | 60 kg 90 kg 45 kg |
Rotor weight (as long as an accommodation of the rotor is possible due to the geometric data and the minimum achievable residual unbalance is sufficient for the balancing task. ) | Min. | unlimited | unlimited | unlimited |
distance between bearing centers (500 mm length machine base) | Max. Min. | 400 mm 21 mm | 400 mm 15 mm | 640 mm 67 mm |
The height from the edge of bearing pedestal to the machine base (without the adaptor) | Max. | 160 mm | 160 mm | 200 mm |
Wn 2 -value for permanent calibration | Wn 2 = 50x10 6 kg/min 2 | Wn 2 = 150x10 6 kg/min 2 | Wn 2 = 500x10 6 kg/min 2 | |
Minimum achievable residual unbalance (U mar ) but not better than (MARU) | 0.1 gmm/kg | 0.1 gmm/kg | 0.1 gmm/kg | |
Unbalance reduction ratio (URR) | ≥ 95 % | ≥ 95 % | ≥ 95 % |